Performance characteristics:
1.Pure sine wave output
2.IP65 waterproof and dustproof makes the inverter available for various working conditions
3.Self-consumption and Feed-in to the grid
4.Programmable supply priority for PV, Battery or Grid
5.Built-in communication port for BMS (RS485), Wi-Fi
6.User-adjustable charging current and voltage
7.Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
8.Dual output for smart load control
9.Parallel operation up to 9 units
MODEL | GSDHW VIV-5KW 48V | GSDHW VIV-6KW 48V |
PHASE | 1-phase in / 1-phase out | |
MAXIMUM PV INPUT POWER | 6000 W | 6500 W |
RATED OUTPUT POWER | 5000VA/5000W | 6000VA/6000W |
MAXIMUM CHARGING POWER | 5000 W | 6000 W |
GRID-TIE OPERATION | ||
PV INPUT (DC) | ||
Maximum DC Voltage | 500 VDC | 550 VDC |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 150 VDC | |
MPP Voltage Range | 120 VDC ~ 450 VDC | |
Number of MPP Trackers / Maximum Input Current | 1 / 27A | 1 / 30A |
GRID OUTPUT (AC) | ||
Nominal Output Voltage | 220/230/240 VAC | |
Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC or 184 - 264.4 VAC (Selectable) | |
Nominal Output Current | 21.7A | 26A |
Power Factor | > 0.99 | |
EFFICIENCY | ||
Maximum Conversion Efficiency (DC/AC) | 95% | |
OFF-GRID OPERATION | ||
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | |
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC | |
Frequency Range | 50 Hz/60 Hz (Auto sensing) | |
Maximum AC Input Current | 40 A | |
PV INPUT (DC) | ||
Maximum DC Voltage | 500 VDC | 550 VDC |
MPP Voltage Range | 120VDC ~ 450 VDC | |
Number of MPP Trackers / Maximum Input Current | 1 / 27A | 1 / 30A |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 220/230/240 VAC | |
Output Waveform | Pure sine wave | |
Efficiency (DC to AC) | 93% | |
HYBRID OPERATION | ||
PV INPUT (DC) | ||
Maximum DC Voltage | 500 VDC | 550 VDC |
Start-up Voltage / Initial Feeding Voltage | 120 VDC / 150 VDC | |
MPP Voltage Range | 120 VDC ~ 450 VDC | |
Number of MPP Trackers / Maximum Input Current | 1 / 27A | 1 / 30A |
GRID OUTPUT (AC) | ||
Nominal Output Voltage | 220/230/240 VAC | |
Output Voltage Range | 184 - 264.5 VAC or 195.5 - 253 VAC or 184 - 264.4 VAC (Selectable) | |
Nominal Output Current | 21.7A | 26A |
AC INPUT | ||
AC Start-up Voltage / Auto Restart Voltage | 120 - 140 VAC / 180 VAC | |
Acceptable Input Voltage Range | 90 - 280 VAC or 170 - 280 VAC | |
Maximum AC Input Current | 40 A | |
BATTERY MODE OUTPUT (AC) | ||
Nominal Output Voltage | 220/230/240 VAC | |
Efficiency (DC to AC) | 93% | |
BATTERY & CHARGER | ||
Nominal DC Voltage | 48 VDC | |
Maximum Solar Charging Current | 100 A | 120 A |
Maximum AC Charging Current | 100 A | 120 A |
Maximum Charging Current | 100 A | 120 A |
GENERAL | ||
PHYSICAL | ||
Dimension, D x W x H (mm) | 192 x 360 x 665 | |
Net Weight (kgs) | 22.5 | |
INTERFACE | ||
Parallel Function | Yes, 9 units | |
Communication Port | USB or RS-232/Dry Contact/RS485/Wi-Fi | |
ENVIRONMENT | ||
Humidity | 0 ~ 95% RH (No condensing) | |
IP degree | IP65 | |
Operating Temperature | -25°C to 50°C |